Generators

Standard Features: double-wall fuel tank, bunding capacity min. 110% fluid, forklift pockets, remote start, two stage heavy duty air filter, earth rod & cable, central lifting point, external emergency stop button, battery isolator switch, protective guard against hot spots, single 80% step load capability, oil sump pump, 4-pole circuit breaker, rigid bus bar terminal (5 poles), voltage adjusting potentiometer, low level coolant shutdown (on G250 and G400 only), earth leakage protection (fixed 300 mA on G40, adjustable on G80, G100, G250 and G400

Options Available

Model G40 G80 G100 G250
Primer power(kVa) 40 80 105 259
Standby power (kVa) 42 88 111 294
Frequency (Hz) 50 50 50 50
Voltages, single phase/ three phase(V) 230/400 230/400 230/400 230/400
Maximum sound power level (LwA) 96 94 96 98
Alternator Leroy Somer Leroy Somer Leroy Somer Leroy Somer
Alternator excitation type AREP AREP AREP AREP
Insulation Class H H H H
Control Panel Analogue Analogue Analogue Analogue
ENGINE  
Make Ingersoll Rand Ingersoll Rand Ingersoll Rand Cummins
Model 41RS2T 41RD5AE 41RD5AE QSL9-G3
Primer power engine (kw) 38 75 94 227
Number of cylinders 4 4 4 6
Electrical system (V) 12 12 12 24
Speed regulator accuracy (Steady State) +/- 2.5% +/- 2.5%q +/-0.25% +/-0.25%
Fuel tank usable capacity (L) 413 716 716 1461
Fuel consumption at 75% Load (L/hr) 8.5 14.9 17.6 49.4
Runtime at 75% load (hr) 8.4 48.0 40.7 29.6
Weight & Dimensions  
LxWxH (mm) 2471x1003x1750 2720x1214x1763 2720x1214x1763 4049x1425x2385
Dry Weight (kg) 1260 1714 1951 3441
Wet Weight (kg) 1649 2377 2614 4783